Bring high quality, safety and reliability to systems and operations
Meisonilan specializes in providing solutions for process control valves and shut-off valves to industries such as energy, chemical engineering, electric power, life sciences, and environmental protection. For many years, our automation technologies have been driving operational optimization. Leveraging our field-proven expertise, we provide support for your low-emission strategies.
Introduction
1. Pneumatic V-shaped regulating ball valve is powered by compressed air, and the valve stem is mechanically transmitted through piston rack and gear. By rotating the ball body by 0-90 ° with torque output from angular stroke, it can complete the opening and closing action or regulating action. By using a matching electrical valve positioner to input a 4-20mA current signal, the rotation angle of the valve core can be changed (any angle from 0-90 °) to adjust and control parameters such as flow rate. Accurate control, small size, light weight, low flow resistance, high flow coefficient, simple structure, and good sealing performance. It is a valve that truly controls the process status with high efficiency.
2. Excellent regulating characteristics: The V-shaped valve has an approximately equal percentage inherent flow characteristic and an adjustable ratio of up to 300:1. Therefore, V-shaped valves can provide precise control over a wide range of variations.
3. Maximum flow volume: Due to its streamlined shape and full right angle rotation control, the maximum volume is particularly high, the flow capacity is particularly large, and the flow resistance is small. Therefore, smaller and more economical valve sizes can be used.
4. The V-shaped valve adopts a dual bearing structure, with high mechanical stability and low starting torque, ensuring excellent sensitivity and sensing speed of the valve.
5. Maximum reliability (safety): The valve body is a solid and durable structure, which is not affected by pipeline pressure during operation and can prevent valve body leakage.
6. Superior sealing performance of metal valve seat: The V-shaped valve adopts an elastic movable metal valve seat, which has self compensation function, superior sealing performance, and ultra long service life. In terms of flow direction, the leakage rate is ≤ 10-5 times the rated flow coefficient.
7. Super strong shear capacity: When the V-shaped valve adopts a metal hard seal structure, the pneumatic V-shaped regulating ball valve core and metal valve seat generate a strong shear force with the V-shaped notch and valve seat during the rotation process, which can cut off impurities such as fibers and has self-cleaning function to avoid valve jamming.
8. The pneumatic actuator adopts a piston type cylinder and a curved arm conversion structure, with a large output torque and small volume precision. The actuator adopts a fully sealed waterproof design with high protection level. The cylinder block adopts a mirror cylinder, oil-free lubrication, low friction coefficient, corrosion resistance, and has super durability and reliability. All transmission bearings adopt boundary self-lubricating bearings without oil lubrication to ensure that the transmission shaft is not worn.


Technical Parameter

Pneumatic Actuator

GT, DA, and AW type angular stroke pneumatic actuators are the driving devices for V-type regulating ball valves. They are available in two types: piston-type double-acting and single-acting (spring return type). They feature a compact double (single) piston gear and rack structure, with precise meshing, smooth transmission, large output torque, flexible and stable operation, light weight, and long service life. (The spring of the single-acting type is pre-compressed before installation, making it easy to install and disassemble, and ensuring good safety.)


GT Type Pneumatic Actuator DA Type Pneumatic Actuator AW Type Pneumatic Actuator

Accessory Options

According to different control and requirements, the following accessories can be selected:
Cut-off type accessories: Single solenoid valve, double solenoid valve, limit switch signal transmitter.
Regulating type accessories: Electric positioner, pneumatic positioner, electric converter.
Air source treatment accessories: Air filter regulator, air source treatment unit.
Manual mechanism: HVSD hand-operated mechanism


Main Part Materials and Applicable Temperature and Medium:

Material\Material Code C P R
Main
Parts
Valve Body WCB ZG1Cr18Ni9Ti ZG0Cr18Ni12Mo2Ti
Ball 2Cr13 ZG1Cr18Ni9Ti ZG0Cr18Ni12Mo2Ti
Valve Stem 2Cr13 1Cr18Ni9Ti 0Cr18Ni12Mo2Ti
Sealing Ring Reinforced PTFE, PARA-polyphenylene, Hardened Alloy Steel
Packing PTFE, Flexible Graphite
Applicable
Working Conditions
Applicable Medium Water, Steam, Oil Nitric Acid and Alkalis Acetic Acid
Applicable Temperature -28°C - 500°C


Flow Characteristics (Inherent Flow Characteristic Curve of Pneumatic V-Type Regulating Ball Valve)


Execution Standards

Design and Manufacturing Standard Flange Size Standard Structure Length Standard Inspection and Test Standard
GB/T12237-89 JB/T79-94 HG20592 GB12221-89 GB/T13927-89 JB/T9092-99
API6D ANSI B16.5 ANSI B16.10 JB/T9092-99
JPI7S-48 JIS B2212~2214 JIS B2002 API598


Product Technical Parameters and Performance Indicators

Nominal Diameter D (mm) 25 32 40 50 65 80 100 125 150 200 250 300
Rated Flow Coefficient Cv 32 47 78 110 170 280 410 750 1120 1850 2950 3800
Nominal Pressure PN (MPa) 1.6, 2.5, 4.0, 6.4
Flow Characteristics Approximately equal percentage (see typical curve), linear characteristic, quick opening
Valve Plate Rotation Angle (degrees) 0° - 90° (adjustable)
Permissible Leakage Class Soft seal: Zero leakage; Hard seal: ≤10 - 5 rated flow coefficient
Action Form Double-acting / Single-acting (spring return type)
Control Type Cut-off type / Regulating type
Actuator Model DA series, GT series, AW series, ZSQ series, etc.
Air Source Pressure Purified compressed air (nitrogen) 0.3 - 0.7 MPa
Regulating Type Input Signal Current signal: 0 - 10 mA, 4 - 10 mA; Air source signal: 20 - 100 kPa
Basic Error With positioner ≤±1.5%
Hysteresis With positioner ≤1.5%
Dead Zone With positioner ≤0.6%
Adjustable Ratio 250:1 300:1
Cut-off Type Signal Voltage AC220V, AC110V, DC24V
Cut-off Time 0.5 S 1.0 S 2.5 - 4.0 S 7.0 S

Permissible Pressure Difference (MPa)

Nominal Diameter 25 32 40 50 65 80 100 125 150 200 250 300
Air Supply 0.5 MPa 5.9 5.4 4.8 4.5 4.3 3.6 2.8 2.0 1.4 1.3 1.1 0.8


Overall Dimensions

Nominal Diameter Dimensions (mm)
Wafer Type Flanged Type
D L L1 D D1 D2 L Z-D
25 64 50 25 115 85 65 102 4-14
40 82 60 25 135 110 85 114 4-18
50 100 75 32 145 125 100 124 4-18
65 120 85 38 160 145 120 145 4-18
80 131 100 45 180 160 135 165 8-18
100 158 115 50 195 180 155 194 8-18
125 180 135 55 215 210 185 213 8-18
150 216 160 65 245 240 210 229 8-23
200 268 200 80 280 295 265 243 12-23
Valve Installation & Maintenance
Valve Installation:
(1) Before installation, check that the product model, tag number, and specifications match the requirements. Inspect the entire valve for missing or loose parts.
(2) Prior to installation, clean the pipeline. Ensure there is sufficient straight pipe section at the valve inlet and install a filter. When connecting the valve body to the pipeline flanges, ensure coaxiality.
(3) Thoroughly clean the pipeline before installing the valve.
(4) The installation site should ensure the safety of personnel and equipment, facilitating operation, disassembly, and maintenance.
(5) The valve should be installed vertically upright on horizontal pipelines. If necessary, it can be installed at an angle, but horizontal installation should be avoided. For occasions with heavy valve weight or vibration, use a support frame.
(6) The medium flow direction must align with the arrow on the valve body. The air supply should be dry and oil-free. The valve should be used in environments with temperatures ranging from -20℃ to 55℃.

Valve Maintenance:
(1) Cleaning the Valve: For general media, cleaning with water is sufficient. For media harmful to health, first understand their properties and then select an appropriate cleaning method.
(2) Disassembly: Remove rust from exposed rusted parts first. Before derusting, protect the machined surfaces of precision parts such as the valve seat, valve plug, valve stem, and push rod. Use special tools when disassembling the valve seat.
(3) Valve Seat: Minor rust or wear on the sealing surface can be repaired by machining. If damage is severe, replace the seat. However, both repaired and replaced hard sealing surfaces must be lapped.
(4) Valve Stem: If the surface is damaged, it must be replaced.
(5) Damage to Push Rod, Guide, and Sealing Surfaces: Reverse-acting actuators must be replaced; direct-acting actuators can be reused after proper repair.
(6) Compression Spring: If there are cracks or other defects affecting strength, replace it immediately.
(7) Wear Parts: Packing, gaskets, and O-rings must be replaced entirely during each maintenance. Check the valve plug and diaphragm for cracks, aging, or corrosion that may cause future failures. Decide whether to replace them based on inspection results, but the diaphragm service life should not exceed 2-3 years.
(8) When reassembling the valve, ensure alignment. Tighten bolts diagonally and lubricate sliding parts. After reassembly, debug the valve according to the factory test items and methods. During this period, accurately adjust the packing compression force and the valve plug closing position.
Ordering Instructions
When placing an order, please fill in the Specification Sheet or specify the following information:
  1. If the model has not been selected before ordering, please provide us with the operating parameters:
    (1) Nominal diameter DN (mm);
    (2) Nominal pressure (MPa or bar);
    (3) Fluid properties (including medium temperature, viscosity, or acidity/alkalinity);
    (4) Pressure before and after the valve (pressure differential);
    (5) Requirements for flow characteristics;
    (6) Materials of valve body and valve core;
    (7) Connection type;
    (8) Driving method (provide air supply pressure, driving voltage);
    (9) Supporting accessories (for pneumatic valves, it is recommended that users install an air filter triplet and a 2-position 5-way solenoid valve);
    (10) On-site working conditions.
  2. If the product model of our company has been selected by the design unit, please order directly from our production department according to the model;
  3. When the application occasion is very important or the pipeline is relatively complex, please provide the design drawings and detailed parameters as much as possible, and our experts will review and check them for you.
Upload order instructions Submit Now
Request Quote
Get your exclusive quotation
  • Your phone number
  • Your email
  • Your name
  • Your company
  • Selected product
  • Request details

National Unified Service Hotline
(086 )0512-68126111
Email: sales@meisonilan.com
Address: No. 2588, Tian'e Dang Road, Hengjing, Wuzhong District, Suzhou City
【Scan WeChat】
Copyright © 2021 Meisonilan Valves (Suzhou) Co., Ltd. All Rights Reserved.
Privacy Policy