Bring high quality, safety and reliability to systems and operations
Meisonilan specializes in providing solutions for process control valves and shut-off valves to industries such as energy, chemical engineering, electric power, life sciences, and environmental protection. For many years, our automation technologies have been driving operational optimization. Leveraging our field-proven expertise, we provide support for your low-emission strategies.
Introduction

The ALSD-400 series high-grade flameproof top valve controller integrates control, valve position feedback, and integral flameproof technology. It realizes the integral flameproofing of the solenoid valve coil and the position transmitter housing, with an explosion-proof rating of Exd II CT6. This significantly reduces the high cost of flameproof products, making the product more competitive.

Explosion-proof rating: Exd II CT6

Technical Parameter
400 C1 S3 M2
Design model
Exd IICT6
S3: Two position three-way valve body

C1: Ordinary coil M2:2SPDT
C2: Low power coil S5: Two position five way valve body M3:3SPDT
C3: Intrinsic safety coil M4:4SPDT
M5:2DPDT
ML2:2SPDT-40℃
PP:P+F(NAMUR)
(ExiaⅡCt6)
PA: Inductance approaching (2or3)
QA: Magnetic proximity (2or3)
F: 4-20mA valve position feedback
T: AS-i fieldbus

Note: More functional options are only applicable to the ALS-300/400/500 series


400 series valve top controller external dimensions

Valve Installation & Maintenance
Valve Installation:
(1) Before installation, check that the product model, tag number, and specifications match the requirements. Inspect the entire valve for missing or loose parts.
(2) Prior to installation, clean the pipeline. Ensure there is sufficient straight pipe section at the valve inlet and install a filter. When connecting the valve body to the pipeline flanges, ensure coaxiality.
(3) Thoroughly clean the pipeline before installing the valve.
(4) The installation site should ensure the safety of personnel and equipment, facilitating operation, disassembly, and maintenance.
(5) The valve should be installed vertically upright on horizontal pipelines. If necessary, it can be installed at an angle, but horizontal installation should be avoided. For occasions with heavy valve weight or vibration, use a support frame.
(6) The medium flow direction must align with the arrow on the valve body. The air supply should be dry and oil-free. The valve should be used in environments with temperatures ranging from -20℃ to 55℃.

Valve Maintenance:
(1) Cleaning the Valve: For general media, cleaning with water is sufficient. For media harmful to health, first understand their properties and then select an appropriate cleaning method.
(2) Disassembly: Remove rust from exposed rusted parts first. Before derusting, protect the machined surfaces of precision parts such as the valve seat, valve plug, valve stem, and push rod. Use special tools when disassembling the valve seat.
(3) Valve Seat: Minor rust or wear on the sealing surface can be repaired by machining. If damage is severe, replace the seat. However, both repaired and replaced hard sealing surfaces must be lapped.
(4) Valve Stem: If the surface is damaged, it must be replaced.
(5) Damage to Push Rod, Guide, and Sealing Surfaces: Reverse-acting actuators must be replaced; direct-acting actuators can be reused after proper repair.
(6) Compression Spring: If there are cracks or other defects affecting strength, replace it immediately.
(7) Wear Parts: Packing, gaskets, and O-rings must be replaced entirely during each maintenance. Check the valve plug and diaphragm for cracks, aging, or corrosion that may cause future failures. Decide whether to replace them based on inspection results, but the diaphragm service life should not exceed 2-3 years.
(8) When reassembling the valve, ensure alignment. Tighten bolts diagonally and lubricate sliding parts. After reassembly, debug the valve according to the factory test items and methods. During this period, accurately adjust the packing compression force and the valve plug closing position.
Ordering Instructions
When placing an order, please fill in the Specification Sheet or specify the following information:
  1. If the model has not been selected before ordering, please provide us with the operating parameters:
    (1) Nominal diameter DN (mm);
    (2) Nominal pressure (MPa or bar);
    (3) Fluid properties (including medium temperature, viscosity, or acidity/alkalinity);
    (4) Pressure before and after the valve (pressure differential);
    (5) Requirements for flow characteristics;
    (6) Materials of valve body and valve core;
    (7) Connection type;
    (8) Driving method (provide air supply pressure, driving voltage);
    (9) Supporting accessories (for pneumatic valves, it is recommended that users install an air filter triplet and a 2-position 5-way solenoid valve);
    (10) On-site working conditions.
  2. If the product model of our company has been selected by the design unit, please order directly from our production department according to the model;
  3. When the application occasion is very important or the pipeline is relatively complex, please provide the design drawings and detailed parameters as much as possible, and our experts will review and check them for you.
Upload order instructions Submit Now
Request Quote
Get your exclusive quotation
  • Your phone number
  • Your email
  • Your name
  • Your company
  • Selected product
  • Request details

National Unified Service Hotline
(086 )0512-68126111
Email: sales@meisonilan.com
Address: No. 2588, Tian'e Dang Road, Hengjing, Wuzhong District, Suzhou City
【Scan WeChat】
Copyright © 2021 Meisonilan Valves (Suzhou) Co., Ltd. All Rights Reserved.