Bring high quality, safety and reliability to systems and operations
Meisonilan specializes in providing solutions for process control valves and shut-off valves to industries such as energy, chemical engineering, electric power, life sciences, and environmental protection. For many years, our automation technologies have been driving operational optimization. Leveraging our field-proven expertise, we provide support for your low-emission strategies.
Introduction

(1) The use of adhesive free lining ensures complete isolation between the medium and metal, improving the reliability of the product.
(2) The sealing surface has good wear resistance (rubber has seven times the wear resistance of copper).
(3) Can be installed in any position, easy to maintain.
(4) The seals can be replaced, and the sealing performance is reliable, achieving bi-directional sealing with zero leakage.
(5) Rubber materials are non-toxic and resistant to bacteria and mold.

Technical Parameter

Application Standards for Electric Flanged Butterfly Valves (Soft Seal)

Design Standard GB/T2238-1989
Flange Connection Dimensions GB/T9113.1-2000; GB/T9115.1-2000; JB78
Structural Length GB/T12221-1989
Pressure Test GB/T13927-2000; JB/T9092-1999

Technical Parameters of Actuators for Electric Flanged Butterfly Valves (Soft Seal)

Actuator Category EI-TORK Series Actuator Parameters EXI-TORK Series Actuator Parameters
Power Supply Voltage Standard: 220V Single-phase Optional: 110V AC Single-phase, 380/440V Three-phase, 24V/110V/220V DC
Output Torque 50N·M~2000N·M 50N·M~4000N·M
Action Range 0~90° 0~360° 0~90°, 0°~270° Optional
Control Mode Switch in-place lamp (On-off two-position control), Passive contact signal, 1/5K potentiometer, Intelligent adjustment (4~20mA analog signal control)
Action Time 15 seconds/30 seconds/60 seconds 18S~112S
Protection Device Overheat protection Built-in overheat protection, Overload protection
Ambient Temperature -30°~60° -20℃~+70℃
Manual Operation Operate with the attached handle Mechanical clutch mechanism, equipped with handwheel for operation
Mechanical Limit Electrical and mechanical double limits Electrical and mechanical double limits
Protection Level IP65 IP65, IP67, Customizable IP68
Explosion-proof Level Non-explosion-proof ExdⅡ BT6, ExdⅡ CT5
Position Measurement Optional switch or potentiometer Potentiometer, Proportional control unit
Drive Motor 8W/E Squirrel-cage asynchronous motor
Inlet Interface 2 G1/2〞M18*1.5 2 PF 3/4”
Shell Material Aluminum alloy Aluminum alloy
Outer Coating Dry powder, Epoxy polyester, with super anti-corrosion function

1) Powerful functions: Intelligent type, Regulating type, On-off type.
2) Compact size: Only about 35% of the volume of similar products.
3) Easy to use: Single-phase power supply, simple wiring; No need for refueling or spot checks, waterproof and rustproof, can be installed at any angle.
4) Protection devices include double limits, overheat protection, and overload protection. The full-stroke time is 15 seconds, 30 seconds, 45 seconds, 60 seconds. And it has a manual function.
5) Intelligent numerical control: The built-in module uses an advanced computer single-chip and intelligent control software to directly receive standard signals (4-20mA DC /1-5VDC) output from computers or industrial instruments to achieve intelligent control and precise positioning of the valve opening.


Part Materials of Electric Flanged Butterfly Valves (Soft Seal)

Part Name Material
Valve Body Ductile cast steel + NBR, Cast steel + NBR, Stainless steel + NBR
Butterfly Plate Gray cast iron, Ductile cast steel, Cast steel, Stainless steel and special materials
Valve Stem 2Cr13, Stainless steel
Packing O-ring, Flexible graphite


Performance Specifications of Electric Flanged Butterfly Valves (Soft Seal)

Nominal Diameter DN (mm) DN50~1200
Nominal Pressure PN (MPa) 0.6 1.0 1.6
Test Pressure Strength Test 0.9 1.5 2.4
Sealing Test 0.66 1.1 1.76
Low-pressure Gas-tight Test 0.5~0.7
Applicable Medium Air, Water, Sewage, Steam, Gas, Oil, etc.


Technical Parameters of Electric Flanged Butterfly Valves (Soft Seal)

Nominal Diameter DN50~450mm
Connection Method Flange
Actuator Selection ODL Compact Type, OHQ Explosion-proof Type
Control Mode On-off type (Electric open, Electric close), Regulating type, Intelligent integrated model
Nominal Pressure PN1.0, 1.6, 2.5Mpa (Please indicate if higher pressure is required)
Power Supply Voltage AC220V, AC380V, DC24V (Please indicate if special voltage is required)
Medium Temperature Carbon steel: -29℃~+425℃
Stainless steel: -40℃~+600℃
Ambient Temperature Standard type: -20℃~+80℃
Protection Level IP65, IP67, IP68
Valve Body Material Carbon steel, Stainless steel
Sealing Material Polytetrafluoroethylene (F), All-metal seal (H)
Cemented carbide (Y)
Operating Conditions Water, Steam, Oil, Nitric acid, Acetic acid


Main Connection Dimensions of Electric Flanged Butterfly Valves (Soft Seal)

Nominal Diameter Overall Dimensions (Reference Values) Connection Dimensions (Reference Values) Actuator Selection
PN1.0MPa PN1.6Mpa
mm Inch L H1 H D2 D1 Z-d D2 D1 Z-d
50 2 161 215 85 82 125 4-18 82 125 4-18 MN-08 MHQ-08
65 21/2 188 280 90 95 145 4-18 95 145 4-18 MNL-10 MHQ-10
80 3 188 258 100 108 160 4-18 108 160 4-18 MNL-15 MHQ-15
100 4 268 310 120 125 180 4-18 125 180 4-18 MNL-20 MHQ-20
125 5 268 310 130 138 210 4-18 138 210 4-18 MNL-30 MHQ-30
150 6 268 315 160 198 240 4-22 198 240 4-22 MNL-40 MHQ-40
22 8 268 380 210 236 295 4-22 236 295 4-22 MNL-60 MHQ-60
250 10 268 460 250 276 355 4-22 276 355 4-26 MNL-80 MHQ-80
300 12 268 475 250 300 410 4-22 308 410 4-26 MNL-100 MHQ-100
350 14 268 510 320 332 470 4-22 340 470 4-26 MNL-200 MHQ-200
400 16 268 550 350 366 525 4-36 374 525 4-30 MNL-300 MHQ-300
450 18 268 590 380 366 585 4-36 384 585 4-30 MNL-400 MHQ-400

Note: The above selection parameters are for reference only. Please refer to the actual situation.

Valve Installation & Maintenance
Valve Installation:
(1) Before installation, check that the product model, tag number, and specifications match the requirements. Inspect the entire valve for missing or loose parts.
(2) Prior to installation, clean the pipeline. Ensure there is sufficient straight pipe section at the valve inlet and install a filter. When connecting the valve body to the pipeline flanges, ensure coaxiality.
(3) Thoroughly clean the pipeline before installing the valve.
(4) The installation site should ensure the safety of personnel and equipment, facilitating operation, disassembly, and maintenance.
(5) The valve should be installed vertically upright on horizontal pipelines. If necessary, it can be installed at an angle, but horizontal installation should be avoided. For occasions with heavy valve weight or vibration, use a support frame.
(6) The medium flow direction must align with the arrow on the valve body. The air supply should be dry and oil-free. The valve should be used in environments with temperatures ranging from -20℃ to 55℃.

Valve Maintenance:
(1) Cleaning the Valve: For general media, cleaning with water is sufficient. For media harmful to health, first understand their properties and then select an appropriate cleaning method.
(2) Disassembly: Remove rust from exposed rusted parts first. Before derusting, protect the machined surfaces of precision parts such as the valve seat, valve plug, valve stem, and push rod. Use special tools when disassembling the valve seat.
(3) Valve Seat: Minor rust or wear on the sealing surface can be repaired by machining. If damage is severe, replace the seat. However, both repaired and replaced hard sealing surfaces must be lapped.
(4) Valve Stem: If the surface is damaged, it must be replaced.
(5) Damage to Push Rod, Guide, and Sealing Surfaces: Reverse-acting actuators must be replaced; direct-acting actuators can be reused after proper repair.
(6) Compression Spring: If there are cracks or other defects affecting strength, replace it immediately.
(7) Wear Parts: Packing, gaskets, and O-rings must be replaced entirely during each maintenance. Check the valve plug and diaphragm for cracks, aging, or corrosion that may cause future failures. Decide whether to replace them based on inspection results, but the diaphragm service life should not exceed 2-3 years.
(8) When reassembling the valve, ensure alignment. Tighten bolts diagonally and lubricate sliding parts. After reassembly, debug the valve according to the factory test items and methods. During this period, accurately adjust the packing compression force and the valve plug closing position.
Ordering Instructions
When placing an order, please fill in the Specification Sheet or specify the following information:
  1. If the model has not been selected before ordering, please provide us with the operating parameters:
    (1) Nominal diameter DN (mm);
    (2) Nominal pressure (MPa or bar);
    (3) Fluid properties (including medium temperature, viscosity, or acidity/alkalinity);
    (4) Pressure before and after the valve (pressure differential);
    (5) Requirements for flow characteristics;
    (6) Materials of valve body and valve core;
    (7) Connection type;
    (8) Driving method (provide air supply pressure, driving voltage);
    (9) Supporting accessories (for pneumatic valves, it is recommended that users install an air filter triplet and a 2-position 5-way solenoid valve);
    (10) On-site working conditions.
  2. If the product model of our company has been selected by the design unit, please order directly from our production department according to the model;
  3. When the application occasion is very important or the pipeline is relatively complex, please provide the design drawings and detailed parameters as much as possible, and our experts will review and check them for you.
Upload order instructions Submit Now
Request Quote
Get your exclusive quotation
  • Your phone number
  • Your email
  • Your name
  • Your company
  • Selected product
  • Request details

National Unified Service Hotline
(086 )0512-68126111
Email: sales@meisonilan.com
Address: No. 2588, Tian'e Dang Road, Hengjing, Wuzhong District, Suzhou City
【Scan WeChat】
Copyright © 2021 Meisonilan Valves (Suzhou) Co., Ltd. All Rights Reserved.