Performance characteristics
- 1. Convenient pressure regulation - The screw type adjustment mechanism makes pressure regulation easier, more convenient, and faster.
- 2. Safety overload - Safety is always the most important in any situation. Self regulating valves, due to their medium directly entering the actuator, often cause serious damage to the valve when the system is overpressure. The overload protection mechanism of this valve can safely withstand overload pressures several times or even tens of times higher than the upper limit of the pressure regulation range.
- 3. No packing - Any frictional resistance during micro pressure control will affect the adjustment accuracy of the pressure regulating valve. The no packing structure of this valve provides good sensitivity to the entire pressure regulating structure while reducing external leakage points.
Product advantages
- 1. The actuator is the main component of the pressure relief valve, which is formed from stainless steel plate and has high compressive strength and service life.
- 2. The principle for determining each structure of the pressure relief valve is to achieve the most convenient installation and maintenance while ensuring performance indicators. Top mounted press in installation allows for internal inspection and maintenance without the need to remove the valve body, and does not require any specialized tools.
Structural characteristics
Valve diameter | 1/2"(DN15)~8"(DN200) |
---|---|
Nominal pressure | ANSI Class 150#~600# |
Usage temperature | -48~+120℃ |
Connection method | Flange type (RF) |
Body material | WCB,CF8,CF8M,CF3,CF3M,etc |
Valve core material | 304(L),316(L),etc. |
Leakage level | ANSI Class IV (rated Cv x 0.01%) |
Rangeability | 20:1 |
Traffic characteristics | Standard Normal |
(1) Before installation, check that the product model, tag number, and specifications match the requirements. Inspect the entire valve for missing or loose parts.
(2) Prior to installation, clean the pipeline. Ensure there is sufficient straight pipe section at the valve inlet and install a filter. When connecting the valve body to the pipeline flanges, ensure coaxiality.
(3) Thoroughly clean the pipeline before installing the valve.
(4) The installation site should ensure the safety of personnel and equipment, facilitating operation, disassembly, and maintenance.
(5) The valve should be installed vertically upright on horizontal pipelines. If necessary, it can be installed at an angle, but horizontal installation should be avoided. For occasions with heavy valve weight or vibration, use a support frame.
(6) The medium flow direction must align with the arrow on the valve body. The air supply should be dry and oil-free. The valve should be used in environments with temperatures ranging from -20℃ to 55℃.
(1) Cleaning the Valve: For general media, cleaning with water is sufficient. For media harmful to health, first understand their properties and then select an appropriate cleaning method.
(2) Disassembly: Remove rust from exposed rusted parts first. Before derusting, protect the machined surfaces of precision parts such as the valve seat, valve plug, valve stem, and push rod. Use special tools when disassembling the valve seat.
(3) Valve Seat: Minor rust or wear on the sealing surface can be repaired by machining. If damage is severe, replace the seat. However, both repaired and replaced hard sealing surfaces must be lapped.
(4) Valve Stem: If the surface is damaged, it must be replaced.
(5) Damage to Push Rod, Guide, and Sealing Surfaces: Reverse-acting actuators must be replaced; direct-acting actuators can be reused after proper repair.
(6) Compression Spring: If there are cracks or other defects affecting strength, replace it immediately.
(7) Wear Parts: Packing, gaskets, and O-rings must be replaced entirely during each maintenance. Check the valve plug and diaphragm for cracks, aging, or corrosion that may cause future failures. Decide whether to replace them based on inspection results, but the diaphragm service life should not exceed 2-3 years.
(8) When reassembling the valve, ensure alignment. Tighten bolts diagonally and lubricate sliding parts. After reassembly, debug the valve according to the factory test items and methods. During this period, accurately adjust the packing compression force and the valve plug closing position.
-
If the model has not been selected before ordering, please provide us with the operating parameters:
(1) Nominal diameter DN (mm);
(2) Nominal pressure (MPa or bar);
(3) Fluid properties (including medium temperature, viscosity, or acidity/alkalinity);
(4) Pressure before and after the valve (pressure differential);
(5) Requirements for flow characteristics;
(6) Materials of valve body and valve core;
(7) Connection type;
(8) Driving method (provide air supply pressure, driving voltage);
(9) Supporting accessories (for pneumatic valves, it is recommended that users install an air filter triplet and a 2-position 5-way solenoid valve);
(10) On-site working conditions. -